Silpakorn University
Nakornpathom
BSL-3 (P3) BioSafety Level 3


   The perfect climate & environment controls system.
  • Temperature
  • Humidity
  • Dewpoint
  • Enthalpy
  • Enthalpy
  • Pressure
  • Cleanliness class
  • Air flow pattern
    IAQ,CO2 and much more...
   Wide range & various climate application  

ENERCOV provides a total solution of climate management system. Airconditioning system is not meaning temperature control only, but could be included the other parameters such as relative humidity, air pressure, dewpoint, moisture content of the air, enthalpy, sensible & latent heat, air flow pattern, wet bulb temperature, saturated temperature, cleanliness class, etc. All of parameters are manageable with ENERCOV's system. The environment management system are designed to various applications such as hospital, operating room, isolation room, biological laboratory, clean room, pharmaceutical, testingroom, calibration room, production line, argicultural, telecommunication, musium, studio, artist hall, library, vaccine production plant, computer room, storage room and much more. An ENERCOV's first project is operated since 2001. After that, we provide all customer satisfied with high accuracy ouput, save energy and lower maintenance cost.

  Room Climate Control Projects

Item Project Name Location Year
Application
1
  SCC DOW Chemical (Cement Thai Group)
 Rayong
2001
 Laboratory
2
  Government Pharmaceutical Organization
 Bangkok
2002
 Drug Production Room
3
  Thai Meiji Pharmarcuetical Co.,Ltd.
 Bangkok
2002
 Pharmarceutical
4
  Silpakorn University
 Nakornpathom
2002
 BSL-3 (P3) BioSafety Level 3
 Laboratory
5
  Samwha Factory
 Chacheongsao
2002
 Capacitor Production Room
6
  MSM Factory
 Leamchabang
2002
 Spring Production Room
7
  A/C Testing Room
 Bangkok
2003
 UL/CE Standard A/C  Performance
 Testing Room
8
  Metler Teledo Co.,Ltd.
 Bangkok
2003
 Instrument Calibration Room
9
  M.C.O.T
 Bangkok
2003
 Telecommunication Room
10
  Government Pharmaceutical Organization
 Bangkok
2003
 Vaccine Production Clean Room
11
  Skill Development of Thailand
 7 Provinces
2003
 Calibration Room
12
  King Mongkut Thonburi University
 Bangkok
2003
 Humidity Control Room
13
  Chulabhorn Research Institute
 Bangkok
2004
 Animal Laboratory
14
  Thai Takeda Lace Co.,Ltd. (Sahabhat   Group)
 Kabinburi
2004
 Raw Material Storage Room
15
  Silpakorn University
 Nakornpathom
2004
 Animal Laboratory Clean Room
16
  UCOM (ITV Project)
 Bangkok
2004
 Telecommunication Room
17
  Internal Commercial Department
 Bangkok
2004
 Instrument Calibration Room
18
  The Supreme Artist Hall
 Pathumthani
2004
 Artist Exhibition Hall
19
  Ekarat Transformer
 Bangkok
2004
 Production Room
20
  Smittivet Hospital
 Bangkok
2004
 Isolation Room
21
  Bangkok Hospital
 Bangkok
2004
 Isolation Room
22
  Jitralada Palace (H.M. The King's Project)
 Bangkok
2004
 Mushroom Laboratory
23
  The Supreme Artist Hall
 Pathumthani
2004
 Artist Musium
24
  Thai Red Cross
 Bangkok
In
progress
 Clean Room Class 10000
25
  Chula. Hospital
 Bangkok
In
progress
 BSL-3 (P3) BioSafety Level 3
 Laboratory
Silpakorn University
Parameters for Controlling...
- Temperature 23°C+/-1°C
- Humidity 50%+/-5%RH
- Room Pressure -10..-30 Pa
- Fresh Air Intake 100%
- Cleanliness Class 10k
- Application Type BSL-3 (P3)
- Air Flow : Non-Laminar
The Supreme Artist Hall
Parameters for Controlling...
- Temperature 24+/-1°C
- Humidity 60%+/-5%RH
- Room Pressure 10-15 Pa
- Fresh Air Intake 10-20%
Chulabhorn Research Institute
Parameters for Controlling...
- Temperature 22-24°C
- Humidity 50%+/-10%RH
- Room Pressure 10-15 Pa
- Virtual Cleanliness class 100k
- Fresh Air Intake 10-20%

Royal Chitralada Projects
Parameters for Controlling...
- Temperature 5-26°C+/-2°C
- Humidity 60-90%+/-5%RH
- Room Pressure 10-15 Pa
- Virtual Cleanliness class 100k
- Fresh Air Intake 10%

Delphi (General Motor)
Suzhou, China
- Temperature 22+/-1°C
- Humidity 50%+/-5%RH
- Room Pressure 10-15 Pa
- Virtual Cleanliness class 100k
- Fresh Air Intake 10%
Nanyang Technological
University (NTU) Singapore
- Temperature 22+/-1°C
- Humidity 50%+/-5%RH
- Room Pressure : Positive
- Fresh Air Intake 10%
 
   
   
   